ISSN 1673-8217 CN 41-1388/TE
Supervisor:China Petrochemical Corporation Limited Sponsor:Sinopec Henan Oilfield Company
2005: Corrosion and protection of catalytic cracking unit and protective measures. Petroleum Geology and Engineering, 19(05): 78-79+102.
Citation: 2005: Corrosion and protection of catalytic cracking unit and protective measures. Petroleum Geology and Engineering, 19(05): 78-79+102.

Corrosion and protection of catalytic cracking unit and protective measures

  • Locations and causes of corrosion on the catalytic cracking unit of Central Petrochemical Plant of Zhongyuan Oilfield are analyzed. It is believed that the main causes of corrosion of the catalytic cracking unit are hydrogen sulphide, carbon dioxide, nitride, NH3, H2O and improper process operation. Process adjustment and application of new technologies can reduce corrosion.